97565C (Rev. J - 8/07)
EDFP210FP*B EDFP214FP*B EDFP217FP*B
Installation/Care/Use Manual
EDFP210FPC EDFP214FPC EDFP217FPC
Soft Sides
Freeze Resistant Fountains
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
EDFP210FPC EDFP217FPC
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA-
TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE
CODES. After installation, leave these instructions inside the fountain for future reference.
This Freeze Resistant Fountain is shipped in two separate cartons. The second carton(s)
contains the Freeze Resistant Package(s) LKFRB1 that are installed on an interior
heated wall. The interior space must maintain a minimum temperature of 50° F (10° C).
Refer to the Freeze Resistant Package for the rough-in dimensions for installation.
Installer
EDFP214FPC
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Installation/Care/Use Manual

97565C (Rev. J - 8/07)EDFP210FP*B EDFP214FP*B EDFP217FP*BInstallation/Care/Use ManualEDFP210FPC EDFP214FPC EDFP217FPCSoft Sides™ Freeze Re

Page 2 - EDFP210FP/EDFP214FP

97565C (Rev. J - 8/07)EDFP210FP*B EDFP214FP*B EDFP217FP*BFIG. 1PAGE 2LEGENDA = MOUNTING BOLT LOCATIONS (4) (3/8" DIA. NOT PROVIDED)B

Page 3 - ROUGH-IN DRAWINGS

97565C (Rev. J - 8/07)EDFP210FP*B EDFP214FP*B EDFP217FP*BPAGE 3FIG. 2FINISHED FLOOR1. Wall should already be framed for the fountain using dim

Page 4 - EDFP217FP

97565C (Rev. J - 8/07)EDFP210FP*B EDFP214FP*B EDFP217FP*BFINISHED FLOORPAGE 4FIG. 3LEGENDA = 3/8" DIA. (10mm) SLOTS (FOR MOUNTING UP

Page 5

97565C (Rev. J - 8/07)EDFP210FP*B EDFP214FP*B EDFP217FP*B1. Wall should already be framed for the fountains using dimensions shown in Fig. 3.

Page 6 - 97565C (Rev. J - 8/07)

97565C (Rev. J - 8/07)EDFP210FP*B EDFP214FP*B EDFP217FP*BPAGE 6FIG. 8FIG. 9FIG. 5FIG. 6See Fig. 9See Fig. 5FIG. 7CABLE SHEATH ADJUSTMENTTo Inc

Page 7

97565C (Rev. J - 8/07)EDFP210FP*B EDFP214FP*B EDFP217FP*BPAGE 7The freeze resistant package must be mounted on an interior wall in a heated ar

Page 8 - PARTS LIST

97565C (Rev. J - 8/07)EDFP210FP*B EDFP214FP*B EDFP217FP*BPAGE 8FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620ELKAY MANUFACTU

Comments to this Manuals

No comments