97634C (Rev. C - 2/04)
HRC4-19-1C HRC4-19-2C
NOTICE: This water cooler must be connected to the water
supply using a dielectric coupling.
NOTE: It is important to insure proper ventilation. Allow a
minimum clearance of 12 inches (305 mm) in front and 3 inches
(76mm) in the rear of the unit. If unit is to be installed in an
enclosure, allow the following clearances around unit - 1 inch
(25mm) each side, 3 inches (76mm) in the rear, 3 inches
(76mm) inches above wall.
This chiller has been designed for use with potable water and
includes an o-ring seal on the drain plug. The fitting should
be replaced if the unit is to be used with more aggressive
fluids.
For use with photo processing applications, adjust
cold control to warmer settings.
HRC419 HRC41950
Refrigeration Packages
Installation Instructions
LEGEND
A = 3/8" O.D. TUBE WATER OUT
B = 3/8" O.D. TUBE WATER INLET
C = 3/8" O.D. TUBE TANK DRAIN